Skip to main content

Table 3 Mean prediction errors and mean absolute prediction errors of differences between preoperative Estimation of axial length and postoperative axial length (the five eyes for which we were unable to obtain preoperative AF-OpB were removed)

From: Optimizing axial length estimation for intraocular lens power calculation in phacovitrectomy for macula-off retinal detachment

 

AF-OpB (n = 51)

FE-OpB (n = 51)

AF-A scan (n = 51)

S-Algor (n = 51)

A-Algor (n = 51)

Mean prediction errors (mm)

0.74 ± 2.22 (-1.31 to 9.15)

-0.17 ± 0.66

(-3.64 to 0.86)

0.12 ± 0.62 (-2.80 to 1.43)

-0.25 ± 0.62 (-3.64 to 0.31)

-0.14 ± 0.71 (-3.64 to 0.83)

Mean absolute prediction errors (mm)

0.87 ± 2.17 (0-9.15)

0.32 ± 0.60 (0 to 3.64)

0.41 ± 0.48 (0.02 to 2.80)

0.28 ± 0.55 (0 to 3.64)

0.35 ± 0.63 (0 to 3.64)

  1. AF-OpB = affected eye’s IOL Master optical biometry, FE-OpB = fellow eye’s IOL Master optical biometry, AF-A scan = affected eye’s A-scan biometry, S-Algor = simple algorithm method, A-Algor = advanced algorithm method